0 of 30 Questions completed
Questions:
You have already completed the practice question before. Hence you can not start it again.
Practice Question is loading…
You must sign in or sign up to start the practice question.
You must first complete the following:
0 of 30 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Average score |
|
Your score |
|
The area of tissue exposed to X-ray radiation should not exceed the minimum coverage required to capture the the desired anatomical area? When aligning the X-ray tube for optimal exposure, how much ALVEOLAR BONE should be shown on a periapical film?
Cephalometric Radiographs evaluate the?
Which of the following does NOT require a protective barrier?
The film has a darkened edge? What is the most likely cause?
What is the correct sequence for manual processing?
What is true when cleaning cassettes?
The most common type of intraoral sensors is the?
An X-ray\’s suitable penetrating power ranges from
Using weak or cold developing solution will result in?
What will prevent static from marring a panoramic image?
The amount of exposure required to produce an image depends on?
What will a processing overlap look like?
Important factors in processing and developing film include?
Which of the following error has MOST likely occurred to a Radiograph when the images are stretched and distorted?
How many types of position indicating devices (PID) are available?
Stand at a _____ from the tube head when taking a Radiograph?
A panoramic will return to start for what reason?
The first solution into which exposed Radiographic film is placed is the?
Operators should perform patient X-rays
During manual processing, to obtain optimum fixing, the film must remain in the fixer solution for?
The patient in this X-ray has ____?
What will static electricity cause on a panoramic image?
The film used to produce panoramic, cephalometric, and TMJ Radiographs is called?
The luminosity of a clinic\’s Radiographic viewbox has decreased over the past few weeks? The most LIKELY cause is?
What is the diameter of collimated X-ray beams?
A panoramic image is extremely dark. What is the likely cause?
When a Radiograph needs to be duplicated, the procedure takes place in the darkroom with what kind of light on?
The anatomic structure that should be included in a bicuspid bitewing Radiograph is-
The best PID length to improve image resolution is-
A restorative material that appears radiopaque on a Radiograph is-